EATON
MGE Comet EX 7 RT Network pack

EATON MGE Comet EX 7RT Network pack

Produktinfo

  • Servers, whether rack-mounted or standing
  • Networking & VOIP
  • Storage
  • Telecom equipement
  • Medical equipment
  • Sensitive electronic equipment in industrial environment
  • High-Density Server virtualization environment

  • 1:1 and 3:1
  • 5/7/11 kVA (6U)
  • True On Line
  • Software Inc.
  • Fully Hot Swappable
  • Density optimised

Comet EX RT 5 KVA 7 KVA 11 KVA
Performances
Active power 5 KVA/ 4 KW ( 1 ) 7 KVA/ 4,9 KW 11 KVA/ 8 KW
Technology On-line double conversion with PFC (Power Factor Correction) system ( 2 )
Rated Input voltage 200/208/220/230/240/250V single phase
380/400/415V three phase
Input Voltage range (- 30 %; + 20 %) 230 V ; (-20 %, + 15 %) 400 V
Input, output frequency range 40-70 Hz, 50 / 60 HZ autoselection, frequency converter as a standard
Output voltage / THDU 200/208/230/240 /250 V +/- 2 %; THDU < 2 %
Overall efficiency normal mode 91 %, eco mode 97 %
THDI THDI < 5 % ( 3 )
Crest factor / short circuit current 3:1 / 100 A 3:1 / 150 A
Overload capacity >150 % 500 ms; 150 % 30 s; 125 % 60 s; 110 % 120 s
Temperature operating 45°C for 8 Hrs( 4 ), 40°C continuous
Back-up times ( 5 ) at 70% load
from 10 up to 15 minutes Standard : 1 power mod. 3U + 1 battery mod. EXB 3U = 6U
from 15 up to 20 minutes Standard + 1 battery mod. EXB 3U = 9U
from 40 up to 65 minutes Standard + 2 battery mod. EXB 3U = 12U
Connection
Input /output terminal block for 13 mm2 (stranded cable) or 10 mm2 (solid cable)
Communication
Port type 6 voltage free contacts DB9 2 A 48V DC, 1 RS 232,
1 RJ 11 for remote power off
Slot 1 slot for minislot communication cards
Standards and certification
Performance and safety IEC 62040-1/CEI 60950/UL 1778 and CSA 22.2 stds( 2 )
EMC IEC 62040-2; EN 50091-2; FCC class A( 2 ), EMC B level( 6 )
Certification UL( 2 )/TÜV , GS mark,CB, C-Tick,CE,
IEC 68-2-6 (vibration tests Marine approval)
Dimensions (H x W x D) in mm; weight (single phase input / three phase input)
Comet EX RT standard backup tower 444,5 x 261,2 x 700
89,5 Kg 88,3 Kg / 89,5 Kg 94,2 Kg / 95,3 Kg
Comet EX RT standard backup Network Pack rack mounting 261,2 (6U) x 444,5 x 700
97,3 Kg 96,1 Kg / 97,3 Kg 102 Kg / 103,1 Kg
Comet EX RT Power module 444,5 x 130,6 x 700 / 130,6 (3U) x 444,5 x 700
24,2 Kg 23 Kg / 24,2 Kg 24,9 Kg / 26 Kg
Battery module Comet EXB RT 444,5 x 130,6 x 650 / 130,6 (3U) x 444,5 x 650
64,5 Kg 64,5 Kg 68,5 Kg
Comet EX RT CLA module / EX RT Transfo. 130,6 (3U) x 444,5 x 650 / 12 Kg / 87 kg
Ratings 5 KVA 7 KVA 11 KVA
Input Voltage 1-phase 3-phase 1-phase 3-phase 1-phase 3-phase
Comet EX RT standard back-up time tower - 68 054 68 070 68 074 68 110 68 114
Network Pack
Rack format( 7 )
- 68 056 68 072 68 076 68 112 68 116
EXB RT Battery Module / EXB RT Battery Module with EPO built-in - 68 078 / 68 079 68118 / 68 119
Comet EX RT Power module (for use with EXB or CLA module) - 68 057 68 075 68 077 68 115 68117
Rack kit for power module
Comet EX RT / Comet EXB RT and CLA
- 68 001 / 68 002
Transformer module - 68003
Comet EX RT CLA module (2 to 8 hours) - 68004
Battery Integration System EX RT ( 8 ) - 68005
EMC B level filter module - - 68 008 - 68 008 -
Comet PDU 19" rack format ( 9 ) - 66 857
1.8 m battery connection cable ( 10 ) - 68 006
UPS Control, remote UPS monitor display - 68 080


Varer som er tilgjengelig på lager, sendes normalt innen 5 dager. Bildet kan avvike fra produktet. Vi tar forbehold mot trykkfeil og endringer av priser og spesifikasjoner uten varsel