EATON
Powerware 9355/ 15kVA Online 230V 15min

EATON Powerware 9355/ 15kVA Online230V 15min

Varenr: 1023818
Lagerstatus: Forventet på lager 13.12.2016
Frakt: 89,- Sjekk din fraktpris
Frakt
Fyll inn postnummer og klikk
knappen for å vise fraktpriser
  Vis priser
3 712,-  inkl. mva
Fra 200,-/mnd (30 mnd)
Utsett betalingen i 4-6 mnd
Velg finansiering i kassen
Kjøp
Produktinfo

With advances in miniaturization and processing power, a single rack of equipment will soon demand 15 to 30 kVA of power—and more equipment than ever will be served by dual-cord power supplies. It’s a challenge to provide power protection for expanding loads in shrinking spaces.

That’s the reality for which Eaton designed the Powerware 9355 UPS. This advanced UPS delivers 10 kVA or 30 kVA of power protection in a sleek tower configuration which includes internal batteries. With such a small footprint, you have more options for locating the UPS and more data center space available for future expansion.

The innovative design of this UPS delivers the industry’s best performance combination of high efficiency, low input current distortion and high power factor. The cumulative result of these advancements is maximum economy, adaptability, and power performance.

Best of all, this advanced technology comes in an easy-to-use product. Installation is easy. You can order the 10-15 kVAUPS with your choice of output receptacles, choosing from 18 types. Later, when you need to change or move data center equipment, simply unplug from the old receptacle, plug into a new one, and go. There’s no need for an electrician to run new conduit and wiring.

The 20-30 kVA models offer features like dual-feed inputs, a 480-volt output transformer, and input and output breakers internal to the UPS.

 

Features and Benefits

  • The double-conversion online design of this “9-series” UPS completely isolates equipment from utility power to protect against all nine of the most common power problems, including outages, sags, surges, spikes, brownouts, line noise, frequency variation, switching transients, and harmonic distortion.
  • The space-saving, attractive design of this compact tower package delivers high power density per square foot. A small footprint also supports more location options, fast and easy installation, lower deployment cost, and more space available for future expansion.
  • A high 0.9 output power factor delivers more power than the vast majority of competitors’ models. This UPS can actually power more equipment than other UPSs of equivalent VA rating that have lower power factors.
  • High efficiency (up to 92 percent across all load ranges) reduces utility costs and runs cooler, which in turn extends component life.
  • Low input current distortion (less than five percent total harmonic distortion, THD), allows maximum transfer of power between power source and protected load, and makes this UPS exceptionally friendly to generators.
  • Powerware Hot Sync technology allows you to parallel up to four equivalent UPS modules for extra capacity or redundancy, ensuring that critical systems are always protected. Parallel configurations can provide up to N+3 redundancy. No inter-module communication wiring is needed. Our patented load-sharing control distributes the load equally and ensures that loads remain fully protected even if a paralleled UPS is unavailable.
  • Eaton’s exclusive ABM® technology uses advanced battery management to significantly increase battery life, using an innovative three-stage charging technique that offers prolonged rest periods between charge phases, as well as temperature-compensated charging that optimizes recharge time.
  • Eaton’s lightweight batteries are user-replaceable. One person, working alone, can replace a battery without disrupting data center operations or power to protected equipment. Extended Battery Modules can be added to extend battery backup time to hours, if desired.
  • The UPS comes with LanSafeä power management software that ensures data and system integrity, using an intuitive, graphical interface and SNMP (Simple Network Management Protocol) to provide control and visibility over multiple UPS products.
  • A complete suite of connectivity options enables secure remote monitoring over your existing LAN or Internet, with real-time performance indicators, prioritized shutdown, testing, and alerts delivered to your network management system, pager, or email.
  • Beyond the warranty period, optional extended service plans are available to match any need—from basic UPS and battery support to advanced remote monitoring with trending, customized UPS and battery capacity planning reports, and comprehensive power protection audits.

Power
Rating  10 kVA and 15 kVA at 0.9 power factor
Topology True double-conversion online UPS
Electrical Input
Nominal input voltage  208V/120V or 220V/127V three phase
Input voltage range  -15%, +10% from nominal at 100% load without depleting battery
Operating frequency  50/60 Hz (45 to 65 Hz)
Input power factor  P.F >0.99 typical, >0.96 frequency converter
Input current distortion  5% THD
Electrical Output
Nominal output voltage   208/120, 220/127 Vac
Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change, <1 ms response time
Efficiency 91% typical
Battery
Battery Type 9Ah, sealed, lead-acid, maintenance-free
Battery Run Time See Battery Runtime Chart
Battery Replacement Field-replaceable
Charger Default is 3.4A per battery string. Charger current is configurable from 0.5 to 25A per string with an overall maximum of 34A (limited by input current)
Start-On-Battery Allows start of UPS without utility input
General
Diagnostics Full system self-test at startup
UPS Bypass Automatic on overload or UPS failure
Parallel for Redundancy and Capacity Yes, using Powerware Hot Sync technology
Dimensions and Weights See Model Selection Table
Overload
(Normal Operation)
150% for 5 sec / 125% for 1 min (online),
110% for 10 min
Communications
LCD Display Graphical LCD with blue backlight
LEDs  (4) LEDs for notice and alarm
Audible Alarms Yes
Communication Ports (1) RS-232, (1) relay contact, (1) REPO,
(2) environmental input
Communication Slot (2) X-Slot communication bays
Power Management Software Bundled Software Suite CD
Environmental
Operating Temperature 10ºC to +40ºC, +45ºC with 7.5% derating;
Batteries recommended max. +25ºC
Storage Temperature -15°C to +25°C
Relative Humidity 0–95%, non condensing
Audible Noise <56dBA at 1 meter (noise less room) typical
Altitude < 1000m at +40°C, < 3000m at +25°C
Certifications
Safety Certifications IEC 62040-1-1, IEC 60950, EN 62040-1-1, UL 1778
EMC Compliance EN 50091-2 Class A
Quality ISO 9001: 2000 and ISO 14001:1996
Markings UL, cUL
Battery Run Times (in minutes)

 VA  Watt  UPS
 + Internal
32 Battery
 (1) EBM 64  (2) EBM 64  (3) EBM 64  (4) EBM 64  UPS
 + Internal
64 Battery
 (1) EBM 96  (2) EBM 96  (3) EBM 96
 15000 13500 4.6 23. 43. 65.1 88.6 13.3 43.0 76.7 113
14500 13050 4.9 24.1 45.2 68.3 93.0 14.1 45.2 80.5 119
14000 12600 5.2 25.2 47.3 71.5 97.4 14.9 47.3 84.2 125
13500 12150 5.5 26.4 49.4 74.7 102 15.8 49.4 88.1 130
13000 11700 5.8 27.6 51.6 78.1 106 16.7 51.6 92.0 136
12500 11250 6.1 28.8 54.0 81.6 111 17.6 54.0 96.2 142
12000 10800 6.5 30.2 56.5 85.5 116 18.6 56.5 101 149
11500 10350 6.9 31.6 59.3 89.7 122 19.2 59.3 106 156
11000 9900 7.3 33.3 62.4 94.4 129 20.2 62.4 111 164
10500 9450 7.8 35.1 65.9 99.6 136 21.4 65.9 117 174
10000 9000 8.4 37.2 69.8 106 144 22.6 69.8 124 184
9500 8550 9.1 39.6 74.2 112 153 24.1 74.2 132 196
9000 8100 9.9 42.3 79.4 120 163 25.7 79.4 141 209
8500 7650 10.8 45.5 85.2 129 175 27.6 85.2 152 225
8000 7200 11.9 49.1 91.9 139 189 29.8 91.9 164 242
7500 6750 13.1 53.2 99.7 151 205 32.3 99.7 178 263
7000 6300 14.6 58.0 109 164 224 35.2 109 194 286
6500 5850 16.3 63.5 119 180 245 38.6 119 212 314
6000 5400 18.4 70.0 131 198 270 42.5 131 234 346
5500 4950 20.1 77.6 145 220 300 47.2 145 259 383
5000 4500 22.4 86.6 162 245 334 52.6 162 289 428
4500 4050 25.2 97.4 182 276 376 59.2 182 325 -
4000 3600 28.6 110 207 313 426 67.1 207 369 -
3500 3150 32.8 127 238 359 - 77.0 238 423 -
3000 2700 38.3 148 277 418 - 89.7 277 - -
2500 2250 45.6 176 329 - - 107 329 - -
Model Selection Table

Order Number1 Description Power
Rating2 (kVA/W)
Input & Output
Voltages4
Battery Backup5 Dimensions
HxWxD (in)
Unit Weight3
(lb)
KA1011100000010 PW9355 with 32-Battery (2-high) 10 kVA / 9kW 208/208 8 32.2 x 12.8 x 33.5 373
KA1012100000010 PW9355 with 64-Battery (3-high)  10 kVA / 9kW  208/208 22 47.8 x 12.8 x 33.5 609
KA1011200000010 PW9355 with 32-Battery (2-high)  10 kVA / 9kW 220/2202 8 32.2 x 12.8 x 33.5 373
KA1012200000010 PW9355 with 64-Battery (3-high)  10 kVA / 9kW 220/2202 22 47.8 x 12.8 x 33.5 609
KA10113400000010 PW9355 with 32-Battery with Transformer (3-high)  10 kVA / 9kW 480/208 8 47.8 x 12.8 x 33.5 577
KA1011300000010 PW9355 with 32-Battery with Transformer (3-high)  10 kVA / 9kW 600/208 8 47.8 x 12.8 x 33.5 577
KA1511100000010 PW9355 with 32-Battery (2-high)  15 kVA / 13.5kW 208/208 4 32.2 x 12.8 x 33.5 373
KA1512100000010 PW9355 with 64-Battery (3-high)  15 kVA / 13.5kW 208/208 13 47.8 x 12.8 x 33.5 609
KA1511200000010 PW9355 with 32-Battery (2-high)  15 kVA / 13.5kW 220/2202 4 32.2 x 12.8 x 33.5 373
KA1512200000010 PW9355 with 64-Battery (3-high)  15 kVA / 13.5kW 220/2202  13 47.8 x 12.8 x 33.5 609
KA15113400000010 PW9355 with 32-Battery with Transformer (3-high)  15 kVA / 13.5kW 480/208 4 47.8 x 12.8 x 33.5 577
KA15113600000010 PW9355 with 32-Battery with Transformer (3-high)  15 kVA / 13.5kW 600/208 4 47.8 x 12.8 x 33.5 577
Power Distribution Module (PDM)

Optional Recepticle Panels Breaker Voltage Phase
(1) L15-30R 30A 208V 3
(1) L21-20R 20A 208/120V 3
(1) L21-30R 30A 208/120V 3
(2) 5-15R 15A 120V 1
(2) 5-20R 20A 120V 1
(2) 6-15R 15A 208V 2
(2) 6-20R 20A 208V 2
(2) L5-15R 15A 120V 1
(1) L5-20R1 20A 120V 1
(1) L5-30R1 30A 120V 1
(2) L6-15R 15A 208V 2
(1) L6-20R1 20A 208V 2
(1) L6-30R1 30A 208V 2
(1) L14-20R1 20A 208/120V 2
(1) L14-30R1 30A 208/120V 2
(2) IEC 320 C13 (120V) 20A 120V 1
(2) IEC 320 C19 (120V) 20A 120V 1
Blank panel      

Tilbehør
EATON INT RELAY I/F CARD
EATON INT RELAY I/F CARD
INT RELAY I/F CARD X-SLOT AS/400
679,-
Kjøp
EATON ConnectUPS-X Web/SNMP. Nätverkskort för
EATON ConnectUPS-X Web/SNMP. Nätverkskort för
1 830,-
Kjøp


Varer som er tilgjengelig på lager, sendes normalt innen 5 dager. Bildet kan avvike fra produktet. Vi tar forbehold mot trykkfeil og endringer av priser og spesifikasjoner uten varsel